• Tel: 086-577-61717596
  • E-mail: info@chyf.com
  •   Outdoor ZW32 1250A Vacuum Circuit Breakers for Switchgear Panel
  • {content:title}

Outdoor ZW32 1250A Vacuum Circuit Breakers for Switchgear Panel

Model: ZW32-12(G)/T

Description:

It is widely used in power distribution, systems of substations and industrial and mining enterprises for control and operation, especially suitable for occasions that need frequent operation.
Accept OEM&ODM:YES
Certificate: CE,Test reports
Production time: 7~ 12 working days
Warranty period: 12 Months
Delivery time: 15 days
Payment term: 50% deposit before production+50% balance before shipment(by T/T,D/P,Paypal)
  • General
  • Technical Parameter
  • ZW32-12(G)/T type outdoor high voltage vacuum circuit breaker (hereinafter called circuit breaker) is suitable for three- phase, AC50Hz with 12KV rated voltage. The circuit breaker is mainly used to break and close the load current, overload current and short circuit current in the power line, with overload and short circuit protection function. It meets control and measurement requirements, as well as remote control and monitor. It is widely used in power distribution, systems of substations and industrial and mining enterprises for control and operation, especially suitable for occasions that need frequent operation. It complies with the technical standard of GB1984- -2003、DL/T 402-207 and IEC60056 etc.

    Model Meaning

    Working Condition

    O Ambient air temperature: Max.+45*C, Min.-40C. O Relative Air Humidity: Daily average is not greater than 95%, month average is not greater than 95%. O  Altitude:≤3000m. O Wind pressure: Not more than 700 Pa (Equivalent to wind speed 34m/s). O  Pollution level: IV (Creepage distance≤31mm/KV). O lcing thickness:≤10mm. O Installation site: should be no fire, explosion hazard, serious pollution, chemical corrosion and severe vibration, etc.  

    Drawing

    Environmental

  • No ltem Unit Data
    1   Rated voltage KV 12
    2   Rated current A 630 1250
    3   Rated frequency Hz 50
    4   Rated insulation level   1 minpower frequency withstand voltage   Dry test KV 42/48(Between open contacts)
      Wet test 34
    Secondary circuit to earth 2
      Lightning impulse withstand voltage (peak 75/85 (Between open contacts)
    5   Rated short circuit breaking current KA 20 25
    6   Rated short-circuit closing current (peak) KA 50 63
    7   Rated short-circuit withstand current KA 20 25
    8   Rated peak withstand current KA 50 63
    9   Rated short-circuit breaking current breaking times Times 30
    10   Rated short circuit duration S 4
    11   Rated operating voltage and auxiliary voltage V DC220、AC220、AC/DC220
    12   Rated operating sequence O-0.3s-CO-180s-CO
    13   Overcurrent release rated current A 5
    14   Mechanical life Times 10000
Copyright@2023 Yufeng Electric Co.,Ltd All Rights Reserved