• Tel: 086-577-61717596
  • E-mail: info@chyf.com
  •   ZW20A-12(24) Outdoor AC Vacuum Circuit Breaker 12 High Voltage Open Circuit Breaker 3 Phase Touch Protection
  • {content:title}

ZW20A-12(24) Outdoor AC Vacuum Circuit Breaker 12 High Voltage Open Circuit Breaker 3 Phase Touch Protection

Model: ZW20A-12(24)

Description:

It uses vacuum arc extinguishing and SF6 gas as the insulating medium, and is an improved product of ZW20 -12 type on-column vacuum circuit breaker. ZW20A-12 outdoor on- -column vacuum circuit breaker is a maintenance- -free product, which is the best among the on-column circuit breakers. 
This product matches the controller and has excellent recloser function to meet the requirements of distribution automation system.
Accept OEM&ODM:YES
Certificate: CE,Test reports
Production time: 7~ 12 working days
Warranty period: 12 Months
Delivery time: 15 days
Payment term: 50% deposit before production+50% balance before shipment(by T/T,D/P,Paypal)
  • General
  • Technical Parameter
  • ZW20A-12 outdoor high voltage vacuum circuit breaker (hereinafter called vacuum circuit breaker) is an outdoor power distribution equipment with rated voltage of 12 KV and three - -phase AC 50 Hz. It uses vacuum arc extinguishing and SF6 gas as the insulating medium, and is an improved product of ZW20 -12 type on-column vacuum circuit breaker.The cabinet adopts the gas sealing, explosion- -proof and insulation structure technology introduced by Japan Toshiba VSP5. The inlet and outlet conduits also have improved sealing performance, and the overall sealing performance is excellent. The SF6 gas flled internally does not leak and is not affected by environmental impacts; its spring operating mechanism is miniaturized and optimized for reliability and stability. It uses a linear chain main drive and a multi-stage trip system.  The reliability and stability of the spring are several times higher than the traditional spring operating mechanism; the contact between the shaft and the sleeve of the main circuit adopts an adduction and external tension type bracelet structure, and the contact resistance of the main circuit is small and the temperature rise is low. Therefore, ZW20A-12 outdoor on- -column vacuum circuit breaker is a maintenance- -free product, which is the best among the on-column circuit breakers. Compared with ZW20-12, ZW20A-12 also adds over-current protection, mechanical spring energy storage indication, and is equipped with aviation socket for secondary electrical connection, which is easy to integrate with intelligent controller. It is widely used for its ecellent electrical and mechanical properties. It is mainly used for breaking and closing the load current and short- circuit current of 10KV power system. It is suitable for protection and control in substation and industrial and mining enterprise power distribution system, and is more suitable for places where the power grid is frequently operated. This product matches the controller and has excellent recloser function to meet the requirements of distribution automation system.

    Working Condition

    O Altitude:≤3000mm. O The upper limit of the ambient air temperature does not exceed 40°C, the lower limit does not exceed - 40C, and the daily temperature difference is 259C. O Wind pressure does not exceed 700Pa. O Pollution level: IV. O  lcing thickness: 100mm. O Installation site: no flammable, explosion hazard, chemical corrosion. O Earthquake intensity does not exceed 8 degrees.

    Drawing

    Environmental

  • No. Item Unit Data
    1 Rated voltage KV 12
    2 Rated frequenc Hz 50
    3 Rated current A 630 1000
    4 Rated short circuit breaking current KA 20 25
    5 Rated peak withstand curren KA 50 63
    6 Rated short-time withstand currenl KA 20 25
    7 Rated short circuit closing current KA 50 63
    8 Rated operating sequence O-0.3s-CO-180s-CO
    9 Rated short circuit duration S 4
    10 Mechanical life Times 10000
    11 Rated current breaking times Times 10000
    12 Rated short circuit breaking times Times 30
    13 Power frequency withstand voltage(1 min) (Wet)phase to phase,to earth KV 34
    (Dry)phase to phase,to earth/between open contacts KV 42/48
    14 Lightning impulse withstand voltage phase,earth/between open contacts KV 75/85
    15 Secondary circuit 1 min power frequency withstand voltage V 2000