• Tel: 086-577-61717596
  • E-mail: info@chyf.com
  •   High quality manual or motorized spring operating mechanism
  • {content:title}

High quality manual or motorized spring operating mechanism

Model:

Description:

The Spring operation mechanism adopts high-precision machining and professional design, which has the characteristics of reliable operation, compact structure, small volume, smooth operation, and long service life. When the power supply fails, it can still complete the operation of disconnecting and closing, which can meet the needs of customers and improve equipment reliability.
  • General
  • Technical Parameter
  • CTO1 type spring operating mechanism is the supporting equipment for XGN-12D AC metal-enclosed switchgear with a rated voltage of 12KV. This series of mechanisms uses flat scroll springs to control the operation of load switches, and the grounding operation is controlled by compression springs. The working positions are closing, opening and grounding. The closing and grounding are equipped with mechanical interlocks to prevent misuse. The product has the characteristics of moderate size, strong installation and applicability. The mechanism complies with the relevant requirements of GB/T3804- 2017 "3.6KV~40.5KV High Voltage AC Load Switch" and GB169262016 "AC High Voltage Load Switch Fuse Combined Appliance".

    Product definition

    YFCT-01 SCDC mechanism operation specification

    Institutional energy storage: Install and fix the mechanism on the body, use a special operating handle, insert it into the upper part of the mechanism (closing operation shaft), and rotate it clockwise about 120° to complete the spring energy storage of the mechanism or the power-on energy storage of the electric operation motor. Closing operation: Press the closing button or electrically operate the closing coil to energize, the spring lone of the energy storage springs) can release the mechanism to drive the body to close, and the main circuit is turned on. Opening or (circuit breaker) tripping operation: Press the opening button lor analog circuit breaker tripping) or electrically operate the opening coil to energize, and another spring can release the mechanism to drive the body to open, and the main circuit is disconnected. Ground closing operation: The operating handle is inserted into the lower part of the mechanism lgrounding operation shaft), and rotated clockwise about 90° . the body is closed by the grounding circuit under the action of the spring force of the mechanism. Ground trip operation: The operating handle is inserted into the lower part of the mechanism lgrounding operation shaft), rotated counterclockwise about 90° . and the body is opened by the grounding circuit under the action of the spring force of the mechanism. There is a mechanical interlock between the closing and opening operations and the grounding operation. In the opening (isolated) state, the closing or grounding can be operated. Once the operation is successful, the other operation will be blocked.

    YFCT-01SJ(G)DJ spring operating mechanism instructions and operating specifications

    Closing operation: Install and fix the mechanism on the body, use a special operating handle, insert it into the upper part of the mechanism (closing operation shafl, and rotate it clockwise about 90° . The body is closed by the main circuit under the action of the spring force of the mechanism or by electric operation. The button motor is energized to drive the mechanism to complete the switch closing operation. Opening operation: The operating handle is inserted into the upper part of the mechanism (closing operation shaft), and rotated counterclockwise about 90° . the main circuit of the main circuit is opened under the action of the elastic force of the mechanism or electrically operated. Press the opening button and the motor is energized to drive the mechanism to complete the switch opening operation. . Ground closing operation: Insert the operating handle into the lower part of the mechanism lgrounding operation shaf), rotate it clockwise about 90*. and the body will close the grounding circuit under the action of the spring force of the mechanism. Ground trip operation The operating handle is inserted into the lower part of the mechanism lgrounding operation shaffl, and rotated counterclockwise about 90*. The main body is opened by the grounding circuit under the action of the spring force of the mechanism.  

    Drawing


    Dimensional drawing of electric outlet spring operating mechanism (F cabinet)



    YFCT-01SJ(G)/DJ spring operating mechanism (C cabinet, V cabinet)



    Dimensions of manual isolation spring operating mechanism (V cabinet)



    Dimensions of electric spring operating mechanism (cabinet C)



    Single hook isolation mechanism



    Single hook wire entry mechanism



    Dimensional installation drawing of manual 3-bar mechanical interlock isolation spring operating mechanism


    Environmental

  • Number Code Name
    1 2YF.1504.0106 Mounting plate (manual override switch)assembly
    2 2YF.1504.0104 Mounting plate (cable door)assembly
    3 2YF.1504.0108 Mounting plate (position switch)assembly
    4 Closing button Green
    5 Split button Red
Copyright@2023 Yufeng Electric Co.,Ltd All Rights Reserved