  •   ZW32-24 High Voltage Pole Mounted Vacuum Circuit Breaker 24kv 630a Outdoor Auto Recloser
  • {content:title}

ZW32-24 High Voltage Pole Mounted Vacuum Circuit Breaker 24kv 630a Outdoor Auto Recloser

Model: ZW32-24

Description:

It can be applied in the construction and renovation of power equipment in different places such as urban and rural network, mines, railways and so on.
Accept OEM&ODM:YES
Certificate: CE,Test reports
Production time: 7~ 12 working days
Warranty period: 12 Months
Delivery time: 15 days
Payment term: 50% deposit before production+50% balance before shipment(by T/T,D/P,Paypal)
  • General
  • Technical Parameter
  • ZW32- -24 outdoor high voltage vacuum circuit breaker (hereinafter referred to as) is suitable for three-phase AC 50Hz, rated voltage 24KV outdoor switchgear. It can be used in various load current and frequent operation occasions. It can be applied in the construction and renovation of power equipment in different places such as urban and rural network, mines, railways and so on. The product has been successfully developed 24 KV outdoor high voltage switchgear suitable for China's national conditions developed on the basis of foreign advanced technology and domestic raw materials and processes. Compared with international similar products, it is a kind of intelligent product with miniaturization and maintenance- -free. At the same time, the product is environmentally friendly without pollution to the surrounding environment. The circuit breaker complies with GB1984- -2003 "High Voltage AC Circuit Breaker", DL/T402 - -2007 "High Voltage AC Circuit Breaker Ordering Technical Conditions", DL/T403- -2000 "12KV~40.5KV High Voltage Vacuum Circuit Breaker Ordering Technical Conditions" and other technical standards.

    Model Meaning

    Working Condition

    O Ambient temperature: -409~+409C. O Relative humidity: Day average relative humidity≤95%, Month average relative humidity≤90%. O Altitude:≤3000mm. OWind pressure: Not more than 700Pa (Equivalent to wind speed 34m/s) O Pollution level: IV (creepage distance≥31mm/KV). Olcing thickness: ≤10mm. O Installation site: Should be no fire, explosion hazard, serious pollution, chemical corrosion and severe vibration,etc.

    Drawing

    Environmental

  • No. ltem Unit Data
    1 Rated voltage KV 24
    2 Rated frequency Hz 50
    3 Rated current A 630 1250
    4 Rated short circuit breaking current KA 20 25
    5 Rated peak withstand current (peak) KA 50 63
    6 Rated short circuit closing current (peak KA 50 63
    7 Rated short-time withstand current /duration KA/s 20/4 25/4
    8 Rated operating sequence O-0.3s-CO-180s-CO
    9 Mechanical life Times 10000
    10 Rated short-circuit breaking current breaking time Times 20
    11 1 min power frequency withstand voltage (Wet)Phase to phase,to earth/Between open contacts KV 50/65
    Dry)Phase to phase,to earth/Between open contacts 65/79
    Secondary circuit 2
    12 Lightning impulse withstand voltage(peak)phase to phase、to earth/ between open contacts KA 125/145
    13 Weight kg 115
Copyright@2023 Yufeng Electric Co.,Ltd All Rights Reserved